Skip to Content

Product Test Condition Change Notification

March 22, 2023

Effective March 22nd, 2023

LG Water Solutions would like to inform you of test condition changes to two of our reverse osmosis membrane elements, as stated below:

LG SW 400 ES
 PreviousNew
Test conditionat 800 psiat 600 psi (STANDARD)at 800 psi (REFERENCE)
Permeate Flow Rate13,700 GPD (51.9 m3/d)6,800 GPD (25.7 m3/d)13,700 GPD (51.9 m3/d)
Stabilized Salt Rejection99.8%99.6%99.8%
Minimum Salt Rejection99.6%99.3%99.6%
Boron Rejection89%81%89%
Permeate Flow Range+-15%+-20%+-15%
LG SW 440 ES
 PreviousNew
Test conditionat 800 psiat 600 psi (STANDARD)at 800 psi (REFERENCE)
Permeate Flow Rate15,070 GPD (57.0 m3/d)7,480 GPD (28.3 m3/d)15,070 GPD (57.0 m3/d)
Stabilized Salt Rejection99.8%99.6%99.8%
Minimum Salt Rejection99.6%99.3%99.6%
Boron Rejection89%81%89%
Permeate Flow Range+-15%+-20%+-15%

The changes are reflected in the respective product pages (and data sheets) below:

LG SW 400 ES

LG SW 440 ES